Minor code structure improvements
This commit is contained in:
parent
ce7bb3fc9a
commit
db64028f2f
3 changed files with 32 additions and 54 deletions
|
|
@ -14,8 +14,7 @@ trap 'graceful_exit' SIGINT SIGQUIT SIGTERM
|
|||
# readonly DELL_FRESH_AIR_COMPLIANCE=45
|
||||
|
||||
# Check if FAN_SPEED variable is in hexadecimal format. If not, convert it to hexadecimal
|
||||
if [[ $FAN_SPEED == 0x* ]]
|
||||
then
|
||||
if [[ $FAN_SPEED == 0x* ]]; then
|
||||
readonly DECIMAL_FAN_SPEED=$(printf '%d' $FAN_SPEED)
|
||||
readonly HEXADECIMAL_FAN_SPEED=$FAN_SPEED
|
||||
else
|
||||
|
|
@ -24,8 +23,7 @@ else
|
|||
fi
|
||||
|
||||
# Check if the iDRAC host is set to 'local' or not then set the IDRAC_LOGIN_STRING accordingly
|
||||
if [[ $IDRAC_HOST == "local" ]]
|
||||
then
|
||||
if [[ $IDRAC_HOST == "local" ]]; then
|
||||
# Check that the Docker host IPMI device (the iDRAC) has been exposed to the Docker container
|
||||
if [ ! -e "/dev/ipmi0" ] && [ ! -e "/dev/ipmi/0" ] && [ ! -e "/dev/ipmidev/0" ]; then
|
||||
echo "/!\ Could not open device at /dev/ipmi0 or /dev/ipmi/0 or /dev/ipmidev/0, check that you added the device to your Docker container or stop using local mode. Exiting." >&2
|
||||
|
|
@ -40,15 +38,13 @@ fi
|
|||
|
||||
get_Dell_server_model
|
||||
|
||||
if [[ ! $SERVER_MANUFACTURER == "DELL" ]]
|
||||
then
|
||||
if [[ ! $SERVER_MANUFACTURER == "DELL" ]]; then
|
||||
echo "/!\ Your server isn't a Dell product. Exiting." >&2
|
||||
exit 1
|
||||
fi
|
||||
|
||||
# If server model is Gen 14 (*40) or newer
|
||||
if [[ $SERVER_MODEL =~ .*[RT][[:space:]]?[0-9][4-9]0.* ]]
|
||||
then
|
||||
if [[ $SERVER_MODEL =~ .*[RT][[:space:]]?[0-9][4-9]0.* ]]; then
|
||||
DELL_POWEREDGE_GEN_14_OR_NEWER=true
|
||||
CPU1_TEMPERATURE_INDEX=2
|
||||
CPU2_TEMPERATURE_INDEX=4
|
||||
|
|
@ -78,19 +74,16 @@ IS_DELL_FAN_CONTROL_PROFILE_APPLIED=true
|
|||
IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT=true
|
||||
IS_CPU2_TEMPERATURE_SENSOR_PRESENT=true
|
||||
retrieve_temperatures $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
|
||||
if [ -z "$EXHAUST_TEMPERATURE" ]
|
||||
then
|
||||
if [ -z "$EXHAUST_TEMPERATURE" ]; then
|
||||
echo "No exhaust temperature sensor detected."
|
||||
IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT=false
|
||||
fi
|
||||
if [ -z "$CPU2_TEMPERATURE" ]
|
||||
then
|
||||
if [ -z "$CPU2_TEMPERATURE" ]; then
|
||||
echo "No CPU2 temperature sensor detected."
|
||||
IS_CPU2_TEMPERATURE_SENSOR_PRESENT=false
|
||||
fi
|
||||
# Output new line to beautify output if one of the previous conditions have echoed
|
||||
if ! $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT || ! $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
|
||||
then
|
||||
if ! $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT || ! $IS_CPU2_TEMPERATURE_SENSOR_PRESENT; then
|
||||
echo ""
|
||||
fi
|
||||
|
||||
|
|
@ -103,39 +96,33 @@ while true; do
|
|||
retrieve_temperatures $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
|
||||
|
||||
# Define functions to check if CPU 1 and CPU 2 temperatures are above the threshold
|
||||
function CPU1_OVERHEAT () { [ $CPU1_TEMPERATURE -gt $CPU_TEMPERATURE_THRESHOLD ]; }
|
||||
if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
|
||||
then
|
||||
function CPU2_OVERHEAT () { [ $CPU2_TEMPERATURE -gt $CPU_TEMPERATURE_THRESHOLD ]; }
|
||||
function CPU1_OVERHEAT() { [ $CPU1_TEMPERATURE -gt $CPU_TEMPERATURE_THRESHOLD ]; }
|
||||
if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT; then
|
||||
function CPU2_OVERHEAT() { [ $CPU2_TEMPERATURE -gt $CPU_TEMPERATURE_THRESHOLD ]; }
|
||||
fi
|
||||
|
||||
# Initialize a variable to store the comments displayed when the fan control profile changed
|
||||
COMMENT=" -"
|
||||
# Check if CPU 1 is overheating then apply Dell default dynamic fan control profile if true
|
||||
if CPU1_OVERHEAT
|
||||
then
|
||||
if CPU1_OVERHEAT; then
|
||||
apply_Dell_fan_control_profile
|
||||
|
||||
if ! $IS_DELL_FAN_CONTROL_PROFILE_APPLIED
|
||||
then
|
||||
if ! $IS_DELL_FAN_CONTROL_PROFILE_APPLIED; then
|
||||
IS_DELL_FAN_CONTROL_PROFILE_APPLIED=true
|
||||
|
||||
# If CPU 2 temperature sensor is present, check if it is overheating too.
|
||||
# Do not apply Dell default dynamic fan control profile as it has already been applied before
|
||||
if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT && CPU2_OVERHEAT
|
||||
then
|
||||
if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT && CPU2_OVERHEAT; then
|
||||
COMMENT="CPU 1 and CPU 2 temperatures are too high, Dell default dynamic fan control profile applied for safety"
|
||||
else
|
||||
COMMENT="CPU 1 temperature is too high, Dell default dynamic fan control profile applied for safety"
|
||||
fi
|
||||
fi
|
||||
# If CPU 2 temperature sensor is present, check if it is overheating then apply Dell default dynamic fan control profile if true
|
||||
elif $IS_CPU2_TEMPERATURE_SENSOR_PRESENT && CPU2_OVERHEAT
|
||||
then
|
||||
elif $IS_CPU2_TEMPERATURE_SENSOR_PRESENT && CPU2_OVERHEAT; then
|
||||
apply_Dell_fan_control_profile
|
||||
|
||||
if ! $IS_DELL_FAN_CONTROL_PROFILE_APPLIED
|
||||
then
|
||||
if ! $IS_DELL_FAN_CONTROL_PROFILE_APPLIED; then
|
||||
IS_DELL_FAN_CONTROL_PROFILE_APPLIED=true
|
||||
COMMENT="CPU 2 temperature is too high, Dell default dynamic fan control profile applied for safety"
|
||||
fi
|
||||
|
|
@ -143,20 +130,17 @@ while true; do
|
|||
apply_user_fan_control_profile
|
||||
|
||||
# Check if user fan control profile is applied then apply it if not
|
||||
if $IS_DELL_FAN_CONTROL_PROFILE_APPLIED
|
||||
then
|
||||
if $IS_DELL_FAN_CONTROL_PROFILE_APPLIED; then
|
||||
IS_DELL_FAN_CONTROL_PROFILE_APPLIED=false
|
||||
COMMENT="CPU temperature decreased and is now OK (<= $CPU_TEMPERATURE_THRESHOLD°C), user's fan control profile applied."
|
||||
fi
|
||||
fi
|
||||
|
||||
# If server model is Gen 14 (*40) or newer
|
||||
if ! $DELL_POWEREDGE_GEN_14_OR_NEWER
|
||||
then
|
||||
if ! $DELL_POWEREDGE_GEN_14_OR_NEWER; then
|
||||
# Enable or disable, depending on the user's choice, third-party PCIe card Dell default cooling response
|
||||
# No comment will be displayed on the change of this parameter since it is not related to the temperature of any device (CPU, GPU, etc...) but only to the settings made by the user when launching this Docker container
|
||||
if $DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE
|
||||
then
|
||||
if $DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE; then
|
||||
disable_third_party_PCIe_card_Dell_default_cooling_response
|
||||
THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Disabled"
|
||||
else
|
||||
|
|
@ -166,8 +150,7 @@ while true; do
|
|||
fi
|
||||
|
||||
# Print temperatures, active fan control profile and comment if any change happened during last time interval
|
||||
if [ $i -eq $TABLE_HEADER_PRINT_INTERVAL ]
|
||||
then
|
||||
if [ $i -eq $TABLE_HEADER_PRINT_INTERVAL ]; then
|
||||
echo " ------- Temperatures -------"
|
||||
echo " Date & time Inlet CPU 1 CPU 2 Exhaust Active fan speed profile Third-party PCIe card Dell default cooling response Comment"
|
||||
i=0
|
||||
|
|
|
|||
28
functions.sh
28
functions.sh
|
|
@ -1,13 +1,13 @@
|
|||
# Define global functions
|
||||
# This function applies Dell's default dynamic fan control profile
|
||||
function apply_Dell_fan_control_profile () {
|
||||
function apply_Dell_fan_control_profile() {
|
||||
# Use ipmitool to send the raw command to set fan control to Dell default
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0x30 0x01 0x01 > /dev/null
|
||||
CURRENT_FAN_CONTROL_PROFILE="Dell default dynamic fan control profile"
|
||||
}
|
||||
|
||||
# This function applies a user-specified static fan control profile
|
||||
function apply_user_fan_control_profile () {
|
||||
function apply_user_fan_control_profile() {
|
||||
# Use ipmitool to send the raw command to set fan control to user-specified value
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0x30 0x01 0x00 > /dev/null
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0x30 0x02 0xff $HEXADECIMAL_FAN_SPEED > /dev/null
|
||||
|
|
@ -17,7 +17,7 @@ function apply_user_fan_control_profile () {
|
|||
# Convert first parameter given ($DECIMAL_NUMBER) to hexadecimal
|
||||
# Usage : convert_decimal_value_to_hexadecimal $DECIMAL_NUMBER
|
||||
# Returns : hexadecimal value of DECIMAL_NUMBER
|
||||
function convert_decimal_value_to_hexadecimal () {
|
||||
function convert_decimal_value_to_hexadecimal() {
|
||||
local DECIMAL_NUMBER=$1
|
||||
local HEXADECIMAL_NUMBER=$(printf '0x%02x' $DECIMAL_NUMBER)
|
||||
echo $HEXADECIMAL_NUMBER
|
||||
|
|
@ -25,9 +25,8 @@ function convert_decimal_value_to_hexadecimal () {
|
|||
|
||||
# Retrieve temperature sensors data using ipmitool
|
||||
# Usage : retrieve_temperatures $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
|
||||
function retrieve_temperatures () {
|
||||
if (( $# != 2 ))
|
||||
then
|
||||
function retrieve_temperatures() {
|
||||
if (( $# != 2 )); then
|
||||
printf "Illegal number of parameters.\nUsage: retrieve_temperatures \$IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT \$IS_CPU2_TEMPERATURE_SENSOR_PRESENT" >&2
|
||||
return 1
|
||||
fi
|
||||
|
|
@ -39,8 +38,7 @@ function retrieve_temperatures () {
|
|||
# Parse CPU data
|
||||
local CPU_DATA=$(echo "$DATA" | grep "3\." | grep -Po '\d{2}')
|
||||
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk "{print \$$CPU1_TEMPERATURE_INDEX;}")
|
||||
if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
|
||||
then
|
||||
if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT; then
|
||||
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk "{print \$$CPU2_TEMPERATURE_INDEX;}")
|
||||
else
|
||||
CPU2_TEMPERATURE="-"
|
||||
|
|
@ -50,8 +48,7 @@ function retrieve_temperatures () {
|
|||
INLET_TEMPERATURE=$(echo "$DATA" | grep Inlet | grep -Po '\d{2}' | tail -1)
|
||||
|
||||
# If exhaust temperature sensor is present, parse its temperature data
|
||||
if $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT
|
||||
then
|
||||
if $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT; then
|
||||
EXHAUST_TEMPERATURE=$(echo "$DATA" | grep Exhaust | grep -Po '\d{2}' | tail -1)
|
||||
else
|
||||
EXHAUST_TEMPERATURE="-"
|
||||
|
|
@ -59,13 +56,13 @@ function retrieve_temperatures () {
|
|||
}
|
||||
|
||||
# /!\ Use this function only for Gen 13 and older generation servers /!\
|
||||
function enable_third_party_PCIe_card_Dell_default_cooling_response () {
|
||||
function enable_third_party_PCIe_card_Dell_default_cooling_response() {
|
||||
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x00 0x00 0x00 > /dev/null
|
||||
}
|
||||
|
||||
# /!\ Use this function only for Gen 13 and older generation servers /!\
|
||||
function disable_third_party_PCIe_card_Dell_default_cooling_response () {
|
||||
function disable_third_party_PCIe_card_Dell_default_cooling_response() {
|
||||
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x01 0x00 0x00 > /dev/null
|
||||
}
|
||||
|
|
@ -88,12 +85,11 @@ function disable_third_party_PCIe_card_Dell_default_cooling_response () {
|
|||
# }
|
||||
|
||||
# Prepare traps in case of container exit
|
||||
function graceful_exit () {
|
||||
function graceful_exit() {
|
||||
apply_Dell_fan_control_profile
|
||||
|
||||
# Reset third-party PCIe card cooling response to Dell default depending on the user's choice at startup
|
||||
if ! $KEEP_THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE_STATE_ON_EXIT
|
||||
then
|
||||
if ! $KEEP_THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE_STATE_ON_EXIT; then
|
||||
enable_third_party_PCIe_card_Dell_default_cooling_response
|
||||
fi
|
||||
|
||||
|
|
@ -102,7 +98,7 @@ function graceful_exit () {
|
|||
}
|
||||
|
||||
# Helps debugging when people are posting their output
|
||||
function get_Dell_server_model () {
|
||||
function get_Dell_server_model() {
|
||||
IPMI_FRU_content=$(ipmitool -I $IDRAC_LOGIN_STRING fru 2>/dev/null) # FRU stands for "Field Replaceable Unit"
|
||||
|
||||
SERVER_MANUFACTURER=$(echo "$IPMI_FRU_content" | grep "Product Manufacturer" | awk -F ': ' '{print $2}')
|
||||
|
|
|
|||
|
|
@ -7,8 +7,7 @@
|
|||
source functions.sh
|
||||
|
||||
# Check if the iDRAC host is set to 'local' or not then set the IDRAC_LOGIN_STRING accordingly
|
||||
if [[ $IDRAC_HOST == "local" ]]
|
||||
then
|
||||
if [[ $IDRAC_HOST == "local" ]]; then
|
||||
# Check that the Docker host IPMI device (the iDRAC) has been exposed to the Docker container
|
||||
if [ ! -e "/dev/ipmi0" ] && [ ! -e "/dev/ipmi/0" ] && [ ! -e "/dev/ipmidev/0" ]; then
|
||||
echo "/!\ Could not open device at /dev/ipmi0 or /dev/ipmi/0 or /dev/ipmidev/0, check that you added the device to your Docker container or stop using local mode. Exiting." >&2
|
||||
|
|
|
|||
Loading…
Add table