Fixed platform check which was not working in LAN mode
This commit is contained in:
parent
e3ee64e4ee
commit
cf69481bbd
2 changed files with 13 additions and 13 deletions
|
|
@ -23,18 +23,6 @@ else
|
||||||
HEXADECIMAL_FAN_SPEED=$(printf '0x%02x' $FAN_SPEED)
|
HEXADECIMAL_FAN_SPEED=$(printf '0x%02x' $FAN_SPEED)
|
||||||
fi
|
fi
|
||||||
|
|
||||||
get_Dell_server_model
|
|
||||||
|
|
||||||
if [[ ! $SERVER_MANUFACTURER == "DELL" ]]
|
|
||||||
then
|
|
||||||
echo "/!\ Your server isn't a Dell product. Exiting." >&2
|
|
||||||
exit 1
|
|
||||||
fi
|
|
||||||
|
|
||||||
# Log main informations
|
|
||||||
echo "Server model: $SERVER_MANUFACTURER $SERVER_MODEL"
|
|
||||||
echo "iDRAC/IPMI host: $IDRAC_HOST"
|
|
||||||
|
|
||||||
# Check if the iDRAC host is set to 'local' or not then set the IDRAC_LOGIN_STRING accordingly
|
# Check if the iDRAC host is set to 'local' or not then set the IDRAC_LOGIN_STRING accordingly
|
||||||
if [[ $IDRAC_HOST == "local" ]]
|
if [[ $IDRAC_HOST == "local" ]]
|
||||||
then
|
then
|
||||||
|
|
@ -50,6 +38,18 @@ else
|
||||||
IDRAC_LOGIN_STRING="lanplus -H $IDRAC_HOST -U $IDRAC_USERNAME -P $IDRAC_PASSWORD"
|
IDRAC_LOGIN_STRING="lanplus -H $IDRAC_HOST -U $IDRAC_USERNAME -P $IDRAC_PASSWORD"
|
||||||
fi
|
fi
|
||||||
|
|
||||||
|
get_Dell_server_model
|
||||||
|
|
||||||
|
if [[ ! $SERVER_MANUFACTURER == "DELL" ]]
|
||||||
|
then
|
||||||
|
echo "/!\ Your server isn't a Dell product. Exiting." >&2
|
||||||
|
exit 1
|
||||||
|
fi
|
||||||
|
|
||||||
|
# Log main informations
|
||||||
|
echo "Server model: $SERVER_MANUFACTURER $SERVER_MODEL"
|
||||||
|
echo "iDRAC/IPMI host: $IDRAC_HOST"
|
||||||
|
|
||||||
# Log the fan speed objective, CPU temperature threshold and check interval
|
# Log the fan speed objective, CPU temperature threshold and check interval
|
||||||
echo "Fan speed objective: $DECIMAL_FAN_SPEED%"
|
echo "Fan speed objective: $DECIMAL_FAN_SPEED%"
|
||||||
echo "CPU temperature threshold: $CPU_TEMPERATURE_THRESHOLD°C"
|
echo "CPU temperature threshold: $CPU_TEMPERATURE_THRESHOLD°C"
|
||||||
|
|
|
||||||
|
|
@ -86,7 +86,7 @@ function gracefull_exit () {
|
||||||
|
|
||||||
# Helps debugging when people are posting their output
|
# Helps debugging when people are posting their output
|
||||||
function get_Dell_server_model () {
|
function get_Dell_server_model () {
|
||||||
IPMI_FRU_content=$(ipmitool fru 2>/dev/null) # FRU stands for "Field Replaceable Unit"
|
IPMI_FRU_content=$(ipmitool -I $IDRAC_LOGIN_STRING fru 2>/dev/null) # FRU stands for "Field Replaceable Unit"
|
||||||
|
|
||||||
SERVER_MANUFACTURER=$(echo "$IPMI_FRU_content" | grep "Product Manufacturer" | awk -F ': ' '{print $2}')
|
SERVER_MANUFACTURER=$(echo "$IPMI_FRU_content" | grep "Product Manufacturer" | awk -F ': ' '{print $2}')
|
||||||
SERVER_MODEL=$(echo "$IPMI_FRU_content" | grep "Product Name" | awk -F ': ' '{print $2}')
|
SERVER_MODEL=$(echo "$IPMI_FRU_content" | grep "Product Name" | awk -F ': ' '{print $2}')
|
||||||
|
|
|
||||||
Loading…
Add table
Add a link
Reference in a new issue