Add new parameter DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_ON_EXIT to allow users to specify whether or not they want the Dell Third-Party PCIe Card Default Cooling Response Logic disabled on exit.
This commit is contained in:
parent
f84367985a
commit
8d56ba7211
3 changed files with 13 additions and 1 deletions
|
|
@ -81,6 +81,7 @@ docker run -d \
|
|||
-e CPU_TEMPERATURE_THRESHOLD=<decimal temperature threshold> \
|
||||
-e CHECK_INTERVAL=<seconds between each check> \
|
||||
-e DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false> \
|
||||
-e KEEP_THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE_STATE_ON_EXIT=<true or false> \
|
||||
--device=/dev/ipmi0:/dev/ipmi0:rw \
|
||||
tigerblue77/dell_idrac_fan_controller:latest
|
||||
```
|
||||
|
|
@ -98,6 +99,7 @@ docker run -d \
|
|||
-e CPU_TEMPERATURE_THRESHOLD=<decimal temperature threshold> \
|
||||
-e CHECK_INTERVAL=<seconds between each check> \
|
||||
-e DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false> \
|
||||
-e KEEP_THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE_STATE_ON_EXIT=<true or false> \
|
||||
tigerblue77/dell_idrac_fan_controller:latest
|
||||
```
|
||||
|
||||
|
|
@ -119,6 +121,7 @@ services:
|
|||
- CPU_TEMPERATURE_THRESHOLD=<decimal temperature threshold>
|
||||
- CHECK_INTERVAL=<seconds between each check>
|
||||
- DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false>
|
||||
- KEEP_THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE_STATE_ON_EXIT=<true or false>
|
||||
devices:
|
||||
- /dev/ipmi0:/dev/ipmi0:rw
|
||||
```
|
||||
|
|
@ -141,6 +144,7 @@ services:
|
|||
- CPU_TEMPERATURE_THRESHOLD=<decimal temperature threshold>
|
||||
- CHECK_INTERVAL=<seconds between each check>
|
||||
- DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false>
|
||||
- KEEP_THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE_STATE_ON_EXIT=<true or false>
|
||||
```
|
||||
|
||||
<p align="right">(<a href="#top">back to top</a>)</p>
|
||||
|
|
@ -157,6 +161,7 @@ All parameters are optional as they have default values (including default iDRAC
|
|||
- `CPU_TEMPERATURE_THRESHOLD` parameter is the T°junction (junction temperature) threshold beyond which the Dell fan mode defined in your BIOS will become active again (to protect the server hardware against overheat). **Default** value is 50(°C).
|
||||
- `CHECK_INTERVAL` parameter is the time (in seconds) between each temperature check and potential profile change. **Default** value is 60(s).
|
||||
- `DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE` parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. **Default** value is false.
|
||||
- `KEEP_THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE_STATE_ON_EXIT` parameter is a boolean that allows to keep the third-party PCIe card Dell default cooling response state upon exit. **Default** value is false, so that it resets the third-party PCIe card Dell default cooling response to Dell default.
|
||||
|
||||
<p align="right">(<a href="#top">back to top</a>)</p>
|
||||
|
||||
|
|
|
|||