Reduced tests occurence to improve performances
This commit is contained in:
parent
a8c12a62c9
commit
2a5a8a03fc
2 changed files with 22 additions and 34 deletions
|
|
@ -50,8 +50,12 @@ fi
|
|||
if [[ $SERVER_MODEL =~ .*[RT][[:space:]]?[0-9][4-9]0.* ]]
|
||||
then
|
||||
DELL_POWEREDGE_GEN_14_OR_NEWER=true
|
||||
CPU1_TEMPERATURE_INDEX=2
|
||||
CPU2_TEMPERATURE_INDEX=4
|
||||
else
|
||||
DELL_POWEREDGE_GEN_14_OR_NEWER=false
|
||||
CPU1_TEMPERATURE_INDEX=1
|
||||
CPU2_TEMPERATURE_INDEX=2
|
||||
fi
|
||||
|
||||
# Log main informations
|
||||
|
|
@ -146,15 +150,19 @@ while true; do
|
|||
fi
|
||||
fi
|
||||
|
||||
# Enable or disable, depending on the user's choice, third-party PCIe card Dell default cooling response
|
||||
# No comment will be displayed on the change of this parameter since it is not related to the temperature of any device (CPU, GPU, etc...) but only to the settings made by the user when launching this Docker container
|
||||
if $DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE
|
||||
# If server model is Gen 14 (*40) or newer
|
||||
if ! $DELL_POWEREDGE_GEN_14_OR_NEWER
|
||||
then
|
||||
disable_third_party_PCIe_card_Dell_default_cooling_response
|
||||
THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Disabled"
|
||||
else
|
||||
enable_third_party_PCIe_card_Dell_default_cooling_response
|
||||
THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Enabled"
|
||||
# Enable or disable, depending on the user's choice, third-party PCIe card Dell default cooling response
|
||||
# No comment will be displayed on the change of this parameter since it is not related to the temperature of any device (CPU, GPU, etc...) but only to the settings made by the user when launching this Docker container
|
||||
if $DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE
|
||||
then
|
||||
disable_third_party_PCIe_card_Dell_default_cooling_response
|
||||
THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Disabled"
|
||||
else
|
||||
enable_third_party_PCIe_card_Dell_default_cooling_response
|
||||
THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Enabled"
|
||||
fi
|
||||
fi
|
||||
|
||||
# Print temperatures, active fan control profile and comment if any change happened during last time interval
|
||||
|
|
|
|||
32
functions.sh
32
functions.sh
|
|
@ -38,24 +38,10 @@ function retrieve_temperatures () {
|
|||
|
||||
# Parse CPU data
|
||||
local CPU_DATA=$(echo "$DATA" | grep "3\." | grep -Po '\d{2}')
|
||||
if $DELL_POWEREDGE_GEN_14_OR_NEWER
|
||||
then
|
||||
# 14 Gen server or newer
|
||||
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk '{print $2;}')
|
||||
else
|
||||
# 13 Gen server or older
|
||||
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk '{print $1;}')
|
||||
fi
|
||||
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk "{print \$$CPU1_TEMPERATURE_INDEX;}")
|
||||
if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
|
||||
then
|
||||
if $DELL_POWEREDGE_GEN_14_OR_NEWER
|
||||
then
|
||||
# 14 Gen server or newer
|
||||
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk '{print $4;}')
|
||||
else
|
||||
# 13 Gen server or older
|
||||
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk '{print $2;}')
|
||||
fi
|
||||
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk "{print \$$CPU2_TEMPERATURE_INDEX;}")
|
||||
else
|
||||
CPU2_TEMPERATURE="-"
|
||||
fi
|
||||
|
|
@ -72,22 +58,16 @@ function retrieve_temperatures () {
|
|||
fi
|
||||
}
|
||||
|
||||
# /!\ Use this function only for Gen 13 and older generation servers /!\
|
||||
function enable_third_party_PCIe_card_Dell_default_cooling_response () {
|
||||
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
|
||||
if ! $DELL_POWEREDGE_GEN_14_OR_NEWER
|
||||
then
|
||||
# 13 Gen server or older
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x00 0x00 0x00 > /dev/null
|
||||
fi
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x00 0x00 0x00 > /dev/null
|
||||
}
|
||||
|
||||
# /!\ Use this function only for Gen 13 and older generation servers /!\
|
||||
function disable_third_party_PCIe_card_Dell_default_cooling_response () {
|
||||
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
|
||||
if ! $DELL_POWEREDGE_GEN_14_OR_NEWER
|
||||
then
|
||||
# 13 Gen server or older
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x01 0x00 0x00 > /dev/null
|
||||
fi
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x01 0x00 0x00 > /dev/null
|
||||
}
|
||||
|
||||
# Returns :
|
||||
|
|
|
|||
Loading…
Add table
Add a link
Reference in a new issue